Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Saudi J Kidney Dis Transpl ; 30(1): 39-44, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30804265

RESUMO

The objective of this study is to determine the impact of a dedicated vascular team in the early detection of complications and improvement of vascular access patency. A dedicated vascular access team comprised four dialysis nurses, a vascular access coordinator and led by a physician. They were assigned for the surveillance and care of all vascular accesses. The team presented problematic cases in the regular quality meeting with documentation of access blood flow, dynamic venous pressure, findings of hematoma, prolonged bleeding, swelling, low arterial pressures, steal syndrome, recirculation studies and dialysis adequacy. In case of failed recirculation or persistently elevated dynamic venous pressure, further evaluation was done either a fistulogram or review by a vascular surgeon. A total of 226 problematic vascular access cases were detected during the study (January 2014 to October 2017). The majority were in 41-70 years age group. A total of 248 referrals were given. Two hundred cases were referred for fistulogram, but it was performed in 188 patients. Vascular access stenosis was detected in 153 patients (81.3%) and angioplasty was performed in 137 (89.5%) of these patients. Fifteen (9.8%) patients were managed conservatively and one patient refused angioplasty. The 15 cases managed conservatively continued to work normally. One patient who refused to angioplasty later clotted his fistula during the follow-up period. Out of 41 cases who were totally noncompliant to referral, nine (22%) clotted their fistula during the follow-up period. In 12 cases in whom fistulogram was requested, but the request was declined by the primary hospital, five patients (41.6%) clotted their fistulas. Subgroup analysis showed that in patients who had both failed recirculation and high venous pressure, the prevalence of stenosis was 90% and angioplasty was performed in 94.4%. In patients who had failed recirculation and low arterial pressure, stenosis was detected in 85.7% and angioplasty was performed in 100% of cases. A dedicated vascular team approach for the care of dialysis vascular access helps in early identification of complications and improve vascular access outcome.


Assuntos
Diálise Renal , Adulto , Idoso , Derivação Arteriovenosa Cirúrgica/estatística & dados numéricos , Oclusão de Enxerto Vascular/epidemiologia , Oclusão de Enxerto Vascular/terapia , Humanos , Pessoa de Meia-Idade , Equipe de Assistência ao Paciente , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/terapia , Estudos Prospectivos , Diálise Renal/efeitos adversos , Diálise Renal/métodos , Diálise Renal/estatística & dados numéricos , Resultado do Tratamento , Dispositivos de Acesso Vascular , Adulto Jovem
2.
Clin Exp Med ; 12(2): 121-5, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21706346

RESUMO

The aim of this study is to investigate the clinical and pathological features and outcome of glomerulonephritis with crescents among adult patients. This is a retrospective study of all cases of crescentic GN seen over a 9-year period (2001-2010). Histological features were assessed, and renal function at baseline and end of follow-up period was recorded. Results among different etiological groups at baseline and end of follow-up period were compared. The mean age in the whole group was 35.6 years (16.2), with the lowest mean in the lupus nephritis (LN) group [27.7 years (9.9)] and the highest in the pauciimmune glomerulonephritis (PIGN) group (P = 0.001). There were 72 cases enrolled in the study. LN accounted for 49.3% of the cases, PIGN for 26.5%, other immune complex glomerulonephritis (ICGN) for 19% and post-infectious GN accounted for 6.3% The majority (85.7%) of the patients had renal impairment at presentation (mean serum creatinine levels were 247 (85) µmol/l, 412 (75) µmol/l and 230 (141) µmol/l in LN, PICN and ICGN, respectively (P = 0.05). Women accounted for 85.3, 76.5 and 36.2% of the patients in LN, PICN and ICGN, respectively (P = 0.025). By the end of the follow-up period of 26 (22.9) months, 25.8% of the patients were requiring dialysis (16.70% in the LN group, 50% in PIGN and 25% in ICGN (P = 0.05) and 21.7% had nephrotic range proteinuria (16.7, 1 and 33.3%, respectively (P = 0.4). Using logistic multivariate analysis, the only independent factors found to predict need for dialysis of prognosis were percent of sclerosed glomeruli (P = 0.05) and presence of ATN (P = 0.028). Baseline proteinuria or SCr, gender and number of glomeruli with crescents, on the other hand, did not impact prognosis. Using linear regression multivariate analysis, SCr, protein excretion and activity score at biopsy did not influence change in SCr or final SCr during the follow-up period. Using ANOVA to compare the groups of LN, PIGN and ICGN), we found significant differences only in gender between LN and ICGN (P = 0.035), in percent glomerular global sclerosis (between LN and PIGN (P = 0.007) and between LN and ICGN (P = 0.012) and in age (between LN and PIGN (P = 0.006). Almost half of our patients with CrGN were due to LN which is higher than that reported by others where PIGN was the more prevalent etiology. Patients with PICN were older and had worse prognosis. This could be explained by the higher number of globally sclerosed glomeruli in the PIGN group.


Assuntos
Glomerulonefrite/epidemiologia , Glomerulonefrite/patologia , Adulto , Distribuição por Idade , Feminino , Glomerulonefrite/complicações , Glomerulonefrite/terapia , Histocitoquímica , Humanos , Rim/patologia , Testes de Função Renal , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Prognóstico , Proteinúria/diagnóstico , Proteinúria/epidemiologia , Diálise Renal , Insuficiência Renal/epidemiologia , Insuficiência Renal/patologia , Estudos Retrospectivos , Arábia Saudita/epidemiologia , Índice de Gravidade de Doença , Distribuição por Sexo , Resultado do Tratamento
4.
Exp Clin Transplant ; 3(1): 338-40, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15989680

RESUMO

OBJECTIVES: To assess the usefulness of isotopic renogram in diagnosing acute renal graft rejection. MATERIALS AND METHODS: Degree of perfusion and allograft uptake of tracer were correlated with the clinical and biopsy diagnoses in 15 postrenal transplant patients with varying degrees of renal impairment. Renographic findings and perfusion calculations were done by a blinded observer. RESULTS: A strong correlation was found between renal histology and renal scan findings in 13 of 15 patients. Sensitivity and specificity of renal scanning in diagnosing acute rejection were 85% and 50% respectively (using renal biopsy findings as the gold standard). CONCLUSION: Our results demonstrate a strong correlation between blinded perfusion assessment and biopsy-proven acute rejection. We conclude, therefore, that single renal flow scan with DTPA (noninvasive/nonnephrotoxic) allows a physician to tailor therapy for acute renal graft dysfunction. We suggest that in cases with a renographic diagnosis of AR, the patient should receive standard antirejection therapy. Renal biopsy should be reserved for those instances when the renographic findings are not definitive and those when the patient fails to respond to a standard methylprednisolone therapy.


Assuntos
Rejeição de Enxerto/diagnóstico por imagem , Rejeição de Enxerto/patologia , Transplante de Rim , Biópsia , Humanos , Rim/diagnóstico por imagem , Rim/patologia , Cintilografia , Sensibilidade e Especificidade , Transplante Homólogo
5.
Am J Nephrol ; 20(5): 364-8, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11092992

RESUMO

We performed a crossover study to compare the effects of different dialysis membranes on 20 patients with frequent dialyser clotting and requiring > or = 5,000 units of heparin per dialysis session. Low-flux dialysers are C15NL (cellulose - Terumo) and E15NL (vitamin-E-coated - Terumo) while high-flux dialysers were F60 (polysulphone) and EE15NL (vitamin-E-coated - Terumo). Ten patients underwent dialysis for 2 months with C15NL then switched to E15NL for 2 months. Similarly, the other 10 patients were started on the high-flux dialyser F60 and then switched over to EE15NL for 2 months. The following parameters were measured at the beginning of the study, 2 weeks, 1 month and then at 2 months: hemoglobin, prothrombin time (PT), partial thromboplastin time (PTT), fibrinogen, protein C, protein S, antithrombin III (ATIII) and factor 12 activity. Dialyser clotting, heparin and erythropoietin requirements were assessed during each dialysis session. There was a significant reduction in clotting with E15NL in comparison to C15NL (22.8 +/- 17 and 44.1 +/- 22.8 (p = 0.0233), respectively). Similarly, heparin requirements were less in the vitamin-E-coated (E15NL) dialysers, 4, 754 +/- 1,427 vs. 6,011 +/- 856 units (p = 0.0281) and erythropoietin usage was also significantly reduced, 4,630 +/- 2,620 vs. 7,850 +/- 4,069 units (p = 0.049). There was a significant increase in hemoglobin with E15NL compared to C15NL, 115 +/- 10.4 vs. 108 +/- 13.1 (p = 0.0343). When the high-flux dialysers were compared there was a tendency towards less dialyser clotting with the EE15NL compared to F60, though this did not achieve statistical significance (p = 0.0561). We could not demonstrate any significant changes between the different dialysers with regards to PT, PTT, fibrinogen factor 12 activity, protein C, protein S and ATIII. In conclusion, we have shown that the use of vitamin-E-modified dialysers is associated with less clotting in patients with persistent clotting problems. In addition, this was associated with less heparin and erythropoietin requirements.


Assuntos
Anticoagulantes/administração & dosagem , Transtornos da Coagulação Sanguínea/prevenção & controle , Materiais Revestidos Biocompatíveis , Eritropoetina/administração & dosagem , Heparina/administração & dosagem , Membranas Artificiais , Diálise Renal/efeitos adversos , Vitamina E/uso terapêutico , Adulto , Anticoagulantes/uso terapêutico , Estudos Cross-Over , Relação Dose-Resposta a Droga , Eritropoetina/uso terapêutico , Feminino , Heparina/uso terapêutico , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
6.
Saudi J Kidney Dis Transpl ; 11(4): 543-7, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-18209342

RESUMO

We performed a crossover study to compare the effect of vitamin E-modified dialyzers on acute intra-dialytic symptoms, with other membranes. Twenty patients on hemodialysis were studied. They were divided into two equal groups of low-flux (C15NL, E15NL) and high-flux (F60, EE15NL) membrane dialyzers. Within each group, a vitamin E-modified dialyzer was compared with another dialyzer in a crossover design over a two-month period. All study patients were seen during each dialysis session by a physician and the occurrence of intra-dialytic symptoms were recorded. There was a significant overall improvement in the incidence of acute intra-dialytic symptoms with the use of vitamin E-modified dialyzers as compared with the other membranes. This effect was more for cuprophane than polysulfone. The occurrence of hypotensive episodes did not differ. Our study indicates that we can achieve a reduction in the incidence of acute intra-dialytic symptoms with the use of vitamin E-modified membrane as compared to cuprophane and polysulfone.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...